1.
Nucleus (La Habana) ; (67): 6-13, ene.-jun. 2020.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1143353

RESUMO

Resumen El Centro de Protección e Higiene de las Radiaciones fue fundado en 1985 para sustentar la aplicación segura de las tecnologías nucleares en Cuba. En la actualidad la institución es considerada como una referencia nacional y regional en materia de seguridad radiológica, gracias a una sólida estrategia institucional que aporta de manera sostenida soluciones a problemas prioritarios del país. Este trabajo presenta una reseña de los principales resultados del centro hasta la fecha.


Abstract The Center for Radiation Protection and Hygiene was founded in 1985 to support the safe application of nuclear technologies in Cuba. Nowdays, the institution is considered as a national and regional reference for radiation protection , thanks to the comprehensive institutional strategy that support the solutions of the problems with priority in the country. The paper presents the overview about the main results of the center up today.

2.
Nucleus (La Habana) ; (59): 34-40, ene.-jun. 2016.
Artigo em Espanhol | LILACS | ID: lil-791486

RESUMO

El Método Monte Carlo fue la base para la estimación de la eficiencia de detección de , utilizando el detector identiFINDER ultra en geometría “tiroides”. Se discute la idoneidad de la metodología de calibración al comparar los resultados del Método Monte Carlo Directo y Corregido, con los valores de eficiencia calculados experimentalmente. El Método Monte Carlo Corregido fue la metodología adoptada debido a que el porcentaje de error estimado, respecto a los resultados experimentales, fue menor que el 10 %. Para las simulaciones, los parámetros geométricos del detector fueron optimizados, utilizando un estudio de tomografía computarizada. El arreglo detector – fuente puntual- fue simulado para obtener los factores de corrección a las distancias prefijadas, y el arreglo detector – maniquí simulador de tiroides- fue simulado para la obtención de la curva de eficiencia de detección, en función de la distancia de medición. Para validar la metodología propuesta, el Laboratorio de Dosimetría Interna del Centro de Protección e Higiene de las Radiaciones participó en un ejercicio de intercomparación regional de estimación, de actividad medida en tiroides, se utilizó para el cálculo de la misma, tanto la metodología tradicional de cálculo de eficiencia como la metodología basada en la utilización del Método Monte Carlo, y se alcanzaron resultados satisfactorios, en todos los casos. Como resultado final de este trabajo, fue obtenida la curva de eficiencia de detección en función de la distancia de , sin necesidad de utilizar simuladores físicos, supliendo, así, la carencia actual de los mismos.


Monte Carlo Method was the base to estimate the detection efficiency of of the identiFINDER ultra detector in “thyroid” geometry. The suitability of the calibration methodology is discussed using a comparison of the results of the Direct Monte Carlo Method and the Transfer Monte Carlo Method calculations with the values of experimentally calculated efficiency. Transfer Monte Carlo Method was the elected methodology because of the differences with the real detection efficiency stay below 10 %. In the simulations, the geometric parameters of the detector were found using a tomography study. The arrangement detector – point source was simulated to obtain the correction factors for preset distances, and the arrangement detector – thyroid phantom was simulated to obtain the detection efficiency curve in function of the distance for . In order to validate the proposed methodology the Internal Dosimetry Laboratory of the Centre for Radiation Protection and Hygiene participated in a regional intercomparison exercise of measured activity estimation in thyroid, for the estimation were used the traditional calculation methodology as well as the methodology base on Monte Carlo Method, the results were satisfactory in both cases. As a final result, the curves of detection efficiency for the measurement of in the thyroid gland was obtained without using physical phantoms, replacing the current lack of it.

3.
Nucleus (La Habana) ; (55): 15-18, ene.-jun. 2014.
Artigo em Espanhol | LILACS | ID: lil-738989

RESUMO

El trabajo muestra los intervalos de monitoreo que se pueden utilizar en el Laboratorio de Contaminación Interna del Centro de Protección e Higiene de las Radiaciones para medir directamente en la glándula tiroides los radionúclidos y . Se emplearon dos sistemas de medición, uno con un detector de centelleo y otro con un detector Phoswich. Ambos detectores se ubicaron dentro de una cámara de bajo fondo de 2.5 x 2.5 x 2.5 m de dimensión recubierta con 15 cm de acero, 3 mm de plomo, 1.8 mm de estaño, y 1.5 mm de cobre. Se calculó la actividad mínima detectable para cada sistema y en función de esta se determinaron los intervalos de monitoreo aplicables, de forma tal que una incorporación correspondiente al 5 % del límite anual de incorporación se pueda detectar. Se obtuvo que para el , todos los intervalos evaluados (120, 90, 60, 30, 14, y 7 días) se pueden utilizar en el monitoreo con ambos sistemas. En el caso del radionúclido , con la instalación del detector de centelleo solo se pueden aplicar los intervalos de 120, 90, y 60 días, y para la instalación con el Phoswich, todos los evaluados.


This paper shows the monitoring intervals that can be used in the Internal Contamination Laboratory of the Center for Radiation Protection and Hygiene for direct measurement of the radionuclides I-125 and I-129 in the thyroid gland. Two measuring systems were used, one of them with a scintillation detector and the other one with a Phoswich detector. Both detectors were placed inside a low background shielding chamber (2.5 x 2.5 x 2.5 m) coated with 15 cm of steel, 3 mm of lead, 1.8 mm of tin and 1.5 mm of copper. The minimum detectable activity for each system was calculated, and based on this, the applicable monitoring intervals were determined, so that an intake corresponding to 5 % of the Annual Intake Limit can be detected. The results showed that for the radionuclide I-125 all the intervals tested (120, 90, 60, 30, 14 and 7 days) can be used in monitoring both systems. In the case of the radionuclide I-129, only the intervals of 120, 90 and 60 days can be implemented by using the scintillation detector whereas for the Phoswich detector, all the tested intervals can be used.